Packaging Details: | 1.HS code is 8504210000; 2.Wooden box with foam inside, 3.No fumigation,not influence the delivery; 4.Standard of CE ISO IEC. 5.Customer OEM packing is also available 6.Can be delivered by air,ship. 5.10 PCS/1*20'ft, too much models and different size. |
Delivery Detail: | Voltage Testing Transformer:15 days after receiving payment |
II.Product Description for Very Low Price AC Hipot Hv Dielectric Strength Testing Transformer :
It is used to test dielectric strength of a variety of electrical products, electrical components, insulation material and other predetermined voltages .
III.Features for Very Low Price AC Hipot Hv Dielectric Strength Testing Transformer :
There are four kinds of high voltage testing transformer according to the medium points:
1. Oil-immersed high voltage transformer test: large capacity, cheap, convenient maintenance, mainstream products.
2. Inflatable high voltage test transformer : interrupter resistance, and light weight.
3. Dry typehigh voltage testing transformer: light weight, light volume, can run backward.
4.Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.
IV.Parameter for Very Low Price AC Hipot Hv Dielectric Strength Testing Transformer :
1.Technical parameters of HZY series alternating current test transformers
Model |
Capacity (KVA) |
Output Voltage (KV) |
Output Current (mA) |
Low Frequency Voltage input | Change | Tempera- ture(ºC)raised/ 30 minute | |
V | A | ||||||
HZY-1.5 | 1.5 | 50 | 30 | 200 | 7.5 | 500 | 10 |
HZY -3 | 3 | 50 | 60 | 200 | 15 | 500 | 10 |
HZY -5 | 5 | 50 | 100 | 200 | 25 | 500 | 10 |
HZY -10 | 10 | 50 | 200 | 220/380 | 50/26 | 500 | 10 |
HZY-20 | 20 | 50 | 400 | 380 | 53 | 500 | 10 |
HZY -30 | 30 | 50 | 600 | 380 | 79 | 500 | 10 |
HZY -40 | 40 | 50 | 800 | 380 | 105 | 500 | 10 |
HZY -50 | 50 | 50 | 1000 | 380 | 132 | 500 | 10 |
HZY -5 | 5 | 100 | 50 | 200 | 25 | 1000 | 10 |
HZY -10 | 10 | 100 | 100 | 200/380 | 50/26 | 1000 | 10 |
HZY -20 | 20 | 100 | 200 | 380 | 53 | 1000 | 10 |
HZY -30 | 30 | 100 | 300 | 380 | 79 | 1000 | 10 |
HZY -40 | 40 | 10 | 400 | 380 | 105 | 1000 | 10 |
HZY -50 | 50 | 100 | 500 | 380 | 132 | 1000 | 10 |
HZY -100 | 100 | 100 | 100 | 500 | 263 | 1000 | 10 |
HZY -150 | 150 | 100 | 1500 | 500 | 300 | 1000 | 10 |
HZY -200 | 200 | 100 | 2000 | 500 | 400 | 1000 | 10 |
HZY -250 | 250 | 100 | 2500 | 380 | 500 | 1000 | 10 |
HZY -20 | 20 | 150 | 133 | 380 | 53 | 1500 | 10 |
HZY -30 | 30 | 150 | 200 | 380 | 79 | 1500 | 10 |
HZY -50 | 50 | 150 | 333 | 380 | 132 | 1500 | 10 |
HZY -100 | 100 | 150 | 666 | 500 | 263 | 1500 | 10 |
HZY -150 | 150 | 150 | 1000 | 500 | 300 | 1500 | 10 |
HZY -200 | 200 | 150 | 1333 | 500 | 400 | 1500 | 10 |
HZY -250 | 250 | 150 | 1666 | 380 | 500 | 1500 | 10 |
HZY -30 | 30 | 200 | 150 | 380 | 79 | 2000 | 10 |
HZY -50 | 50 | 200 | 250 | 380 | 132 | 2000 | 10 |
HZY -100 | 100 | 200 | 500 | 380 | 263 | 2000 | 10 |
HZY -150 | 150 | 200 | 750 | 500 | 300 | 2000 | 10 |
HZY -200 | 200 | 200 | 1000 | 500 | 400 | 2000 | 10 |
HZY -250 | 250 | 200 | 1250 | 500 | 500 | 2500 | 10 |
HZY -30 | 30 | 250 | 120 | 380 | 79 | 2500 | 10 |
HZY -50 | 50 | 250 | 200 | 380 | 132 | 2500 | 10 |
HZY -100 | 100 | 250 | 400 | 380 | 263 | 2500 | 10 |
HZY -150 | 150 | 250 | 600 | 500 | 300 | 2500 | 10 |
HZY -200 | 200 | 250 | 800 | 500 | 400 | 2500 | 10 |
HZY -250 | 250 | 250 | 1000 | 500 | 500 | 2500 | 10 |
2. Technical parameters of TDM alternating and direct current test transformers
Model |
Capacity (KVA) |
Output (KV) |
Current (Ma) |
Low voltage input | Change | Tempera- ture(ºC)raised/ 30 minute | |||
AC | DC | AC | DC | V | A | ||||
TDM -1.5 | 1.5 | 50 | 70 | 30 | 15 | 200 | 7.5 | 500 | 10 |
TDM -3 | 3 | 50 | 70 | 60 | 15 | 200 | 15 | 500 | 10 |
TDM -5 | 5 | 50 | 70 | 100 | 15 | 200/380 | 25 | 500 | 10 |
TDM -10 | 10 | 50 | 70 | 200 | 100 | 380 | 50/26 | 500 | 10 |
TDM -20 | 20 | 50 | 70 | 400 | 100 | 380 | 53 | 500 | 10 |
TDM -30 | 30 | 50 | 70 | 600 | 100 | 380 | 79 | 500 | 10 |
TDM -40 | 40 | 50 | 70 | 800 | 100 | 380 | 105 | 500 | 10 |
TDM -50 | 50 | 50 | 70 | 1000 | 100 | 380 | 132 | 500 | 10 |
TDM -5 | 5 | 100 | 140 | 100 | 50 | 200/380 | 25 | 1000 | 10 |
TDM -10 | 10 | 100 | 140 | 200 | 100 | 380 | 50/26 | 1000 | 10 |
TDM -20 | 20 | 100 | 140 | 300 | 100 | 380 | 53 | 1000 | 10 |
TDM -30 | 30 | 100 | 140 | 400 | 100 | 380 | 79 | 1000 | 10 |
TDM -40 | 40 | 100 | 140 | 600 | 100 | 380 | 105 | 1000 | 10 |
TDM -50 | 50 | 100 | 140 | 1000 | 100 | 380 | 132 | 1000 | 10 |
V.Detailed Photos for Very Low Price AC Hipot Hv Dielectric Strength Testing Transformer :
VI.Company Information
HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.
What's more, our customers come from different countries like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.
Our main products are Insulation Oil Tester, Cable Fault Locator, Power Quality Analyzer, High Voltage Generator, High Voltage Capacitor, Testing Transformer and so on.
VII.Exhibition
VIII.Customer Visit
IX.Similar models:
DC high voltage tester
AC vlf high voltage tester